Current location - Plastic Surgery and Aesthetics Network - Plastic surgery and medical aesthetics - How to use the car beam straightener to correct the car?
How to use the car beam straightener to correct the car?
Safety matters of body calibration:

1. Pay full attention to safety when using the car beam calibrator. Otherwise, the calibration may fail or the calibration equipment may be damaged.

2. Before traction correction, protect the parts inside and outside the car body, such as seats, instruments and car cushions. Remove the external parts of the car body and protect the car body with cotton cloth to prevent scratches. If there are scratches on the paint surface, they must be repaired to prevent corrosion.

After the car body is corrected and repaired by using the car beam calibrator, the final inspection should be carried out in time. Inspection is divided into two cases: when the fixing device is not used for repair, the final measurement inspection should be made and compared with the size manual of the car body and frame to determine whether the requirements of car body correction are met. When repairing on the fixing device, it is not necessary to measure, but only to judge whether the control points of the car body match the fixing device.

Attention should be paid to when using the automobile beam calibrator:

1. Wear work clothes and gloves when entering the work area; Slippers and high heels are not allowed in.

Two. Pre-operation inspection

1. Before the equipment is operated, the site shall be cleaned, sundries shall not be piled up on the platform and around it, and the oil and gas pipelines shall be tidied up to prevent the pipelines from being squeezed during operation;

2. Check whether the oil and gas pipeline joints are well connected and whether the pipeline is damaged. If it is damaged, replace it in time, and reuse is strictly prohibited;

3. Check whether the fixing bolts of the rolling pulley of the tower column are loose and tighten them in time, so as to avoid personal injury and articles injury caused by the sliding of the tower column.

3. Getting on and off operating procedures

1. When the car straightening platform lifts, it is forbidden to stand near the equipment. When getting on and off the car, someone must guide it, and the car should be parked at the designated position of the platform;

2. When the platform is hoisted, it should be operated smoothly. When there is no throttle valve in the wheel leg cylinder of the platform, it is forbidden to fully open the oil pump pressure relief valve;

3. When the platform takes off and lands, the tower column is fixed at the other end of the platform to prevent sliding; The secondary lifting is placed at one side close to the movable leg;

4. The vehicle should tighten the parking brake on the platform, and the front and rear tires should be padded with triangular wood;

5. After the platform rises, the movable legs of the main girder corrector platform must be locked.

4. Vehicle fixed operation procedures

1. Check the jaws before clamping the fixture, and there should be no oil stain and sundries;

2. Check whether there is any deformation and crack in each part of the fixture, and replace it if there is any, so as to prevent it from breaking and flying out after being stressed and hurting people;

3. The main fixture fixing bolt and the jaw fastening bolt should be completely tightened.

Verb (abbreviation of verb) measurement operation procedure

1. The measuring tool should be handled with care, without collision, to prevent deformation and damage of the measuring tool;

2. When measuring the reading, glasses should be parallel to the reading part to reduce the reading error;

3. After the measurement is completed, the measuring tools should be immediately put back to the original position of the tool cart;

4. Fix the measuring tool. After the connecting screw is loose, tighten it again. Don't use too much force.