Garden lamp installation:

4.3.5. 1 The insulation resistance of the conductive part of each group of lamps to the ground is greater than 10 (2) mω.

4.3.5.2 vertical street lamps, floor-standing street lamps, special courtyard lamps and other lamps are fixed and reliable with the foundation, and all the anchor bolts are capped. The waterproof gaskets of junction box, fuse box and lamp box cover are complete.

The automatic on-off power supply control device of 4.3.5.3 lamps works accurately, and the fuses in the fuse box of each set of lamps are complete and the specifications are suitable for lamps.

4.3.5.4 metal columns and lamps can be reliably grounded (PE) or grounded (PEN) close to bare conductors. The grounding wire is a single trunk line, which forms a ring network along the layout position of the courtyard lamp and is connected with the lead-out wire of the grounding device at least twice. The branch lines led from the main line are connected with the grounding terminals of metal lamp poles and lamps, and marked.

The street lamps on overhead poles in 4.3.5.5 are fixed reliably, the fasteners are complete and fastened, and the lamp position is correct; Each group of lamps is equipped with fuse protection.

4.4 Power-on debugging:

Lamps and lanterns, distribution box (panel) are installed, and the insulation resistance of each branch is qualified before power-on trial operation is allowed. Check the patrol carefully after electrifying, and check whether the lamp control is flexible and accurate; Switches correspond to the control sequence of lamps. If you find any problems, you must turn off the power first, and then find the cause for maintenance.

5 quality control

5. 1 The deviation of the center line of lamps in rows is beyond the allowable range: when determining the position of lamps in rows, the crosshairs must be pulled.

5.2 The grounding (PE) or zero connection (PEN) of metal frames and lamps that can be close to bare conductors and metal hoses is reliable and marked.

5.3 The frame of lamps and lanterns should be fixed reliably, the anchor bolts should be fastened and the lamp holders should be complete; The bolts of lamps and lanterns are fastened without omission. Exposed wires or cables of lamps shall be protected by flexible metal conduits.

5.4 Connect the flexible cord buckle of lamps and lanterns with tin-lined pressing wire. When the screw cap is used, the phase wire is connected to the terminal in the middle of the screw cap.

5.5 The glass cover of large lamps installed in important places should prevent the glass cover from splashing after being broken.

5.6 The pedestal and bracket of floodlight shall be fixed firmly, and the pivot shall be screwed and fixed along the required optical axis.

5.7 The applicable places and installation methods of various lamps shall be installed with reference to the installation schematic diagram and instructions provided by the manufacturer.

6 quality standards

6. 1 6. 1 main project

6. 1. 1 The installation of building lamps shall meet the following requirements:

6. 1. 1. 1 The lantern on the roof adopts a special lamp with rainproof performance, and the lampshade should be tightened;

6. 1.65438+ The pipeline, the pipeline, the lamp holder box, the metal conduit, the lantern frame and the steel cable are connected by threads. Reliable grounding (PE) or zero connection (PEN) of the accessible bare conductor;

6. 1. 1.3 The cantilever for hanging vertical lanterns shall be made of channel steel not less than 10 #. The diameter of the hook bolt at the end used to hang the wire rope is not less than 10mm, the bolt is fixed on the channel steel, there are nuts on both sides, and it is fastened with a flat pad and a spring washer;

6. 1. 1.4 The diameter of the suspension wire rope is not less than 4.5mm, the diameter of the round steel bar at the bottom is not less than 16mm, and the ground anchor adopts the overhead perimeter of the cable tray, and the buried depth is more than1.5 m;

6. 1. 1.5 vertical lamps adopt waterproof hanging wire lamp holders, and the lower lamp holder is higher than 3m from the ground.

6. 1.2 neon lamp installation shall meet the following requirements:

6. 1.2. 1 Neon lamp tube is intact and not broken;

6. 1.2.2 The lamp tube is fixed with special insulating bracket, which is firm and reliable. After the lamp is fixed, the distance from the surface of buildings and structures shall not be less than 20mm.

6. 1.2.3 Double-ring transformer for neon lights, the length of the supplied lamp tube is not greater than the allowable load length, and outdoor rainproof measures are installed;

6. 1.2.4 The connecting wire between the secondary line of the neon lamp special transformer and the lamp tube adopts high-voltage insulated conductor with rated voltage greater than 15KV. The distance between the secondary line and the surface of buildings and structures shall not be less than 20mm.

6. 1.3 The installation of architectural landscape lighting lamps shall meet the following requirements:

6. 1.3. 1 The insulation resistance of the conductive part of each group of lamps to the ground is greater than10 (2) mω;

6. 1.3.2 Floor lamps installed in crowded places such as sidewalks are not protected by fences, and the installation height is more than 2.5m from the ground;

6. 1.3.3 The bare conductor that can be touched by metal frames and lamps and lanterns and the grounding (PE) or zero connection (PEN) of metal hoses are reliable and marked.