Current location - Plastic Surgery and Aesthetics Network - Plastic surgery and medical aesthetics - How to design a dental clinic logo
How to design a dental clinic logo

Dental clinic design:

1. In clinic design, the only standard to be followed is: function is the foundation, and image is the beautification and sublimation based on the function.

2. The front desk of the clinic is the essence of the entire clinic.

Functional design: No matter how good the image is, after two years of clinic operation, it will lose the freshness of its original image. At this time, whether the function can have good results is to test the clinic front desk design. The standard of good and bad.

The clinic front desk/front office is the beginning of the entire service and the beginning of the entire sales. It can do many things in the 5-10 minutes it takes the patient's time.

Our working procedures are usually: determining functions - functional classification - division of similar functional areas - division of auxiliary dispersed functional areas - design of personnel travel routes - refinement of service items in each functional area - production of special service hardware -After confirmation, beautify the design

Appearance

The style of each clinic should be set according to different venues, sizes, and heights.

Design points:

①The reception desk should face the door.

②The relevant introduction of the clinic should be placed where patients can stop.

③The diagnosis and treatment guide introduction should be designed according to the patient’s route.

④Staff can easily monitor and view all reception areas.

⑤The internal working area cannot be seen by patients who have just entered the door.

3. The main function of the clinic is treatment, so when designing the clinic, you should pay more attention to the use of functions:

Detailed design: How to clean better?

Let’s not talk about how to diagnose and treat the clinic first, let’s first look at how to clean it.

In the decoration of the floor, different colors should be used to divide different sanitary functional areas.

The designed furniture is mostly non-floor-standing to facilitate future cleaning work.

The design of the garbage disposal port should be convenient for nurses to clean, and it should also be positioned on the container for holding garbage.

The cleaning area, cleaning area, and administrative area should be clearly distinguished, and color, style, location, etc. should be used in the decoration to separate the above functional areas. The most difficult thing is the location design.

The design of the skirting line is a very important link in whether the clinic can maintain good sanitary conditions, and it is often ignored.

It is recommended that the skirting line use marble or special materials. tile so that the baseboards won't be stained during future cleanings.

The design of light can improve the illumination of the clinic, visually improve the brightness of the walls and side cabinets, and make it appear more hygienic.

The arrangement of lighting can divert the patient's attention, and combined with wall decoration, can display the theme of the clinic.

Line layout: including waterways, electrical circuits, and gas lines, mainly considering the issues of capacity expansion, maintenance, and route modification.

4. The overall structure of a clinic is a complete reflection of the processes and arrangements of a clinic owner.

In the entire design, the usage frequency of each part to be put into the design should be calculated cumulatively, the size, quantity and other attribute factors of each functional part should be set, and then the functional part should be connected with the attribute part. Through the restriction parameters of frequency of use, probability of use, route retracement, etc., the locations of each room, reception, general area, waiting room, X-ray room, disinfection, etc. are finally determined, and the route of the flow of people is controlled to the most economical way, and more intersections are used. Routes, use less repeated routes.

5. Arrange clinic design based on the quality and composition of clinic personnel

The full function of a clinic has a lot to do with the composition and quality of personnel within the clinic. If a clinic does not have more skilled nursing staff, then the central desk design method should be used in the design of the entire monitoring station, and skilled nursing staff should be placed in the middle position, so that their supervision can be fully utilized. The role of guidance drives the service level of the entire clinic. This is more suitable for the design of large public clinics.

If the clinic has more skilled employees, the level will be average. In the design, more attention should be paid to the demarcation of separate and secret areas. This can provide customers with a quieter and more private medical treatment space, which is more suitable for the design of high-end clinics.

Decoration of modern dental clinic:

(1) Settings of dental clinic

1. Waiting room

⑴Service desk: Mainly responsible for reception, consultation, medical guidance, calling, medical record management, and charging.

⑵ Layout: There are sofas, tea, flowers or bonsai; books, magazines, pictorials, abstracts, and oral health education materials for patients to read; film and television equipment can play oral health education knowledge, or scenery films, Comedies etc.

⑶ There should be restrooms around the waiting room, and dressing tables should be set up if possible for patients to wash their hands or apply makeup

2 Clinics

(1) Treatment Work area: Comprehensive treatment table, assistant operating table, medical records office table

(2) Coordinating treatment area

3. X-ray room

Dental X-ray X-ray machines and oral surface tomography machines are essential inspection and diagnostic equipment in dental clinics. Foreign dental clinics generally install dental radiograph machines next to the dental chair, but China's health and epidemic prevention agencies do not allow this.

Therefore, the clinic must establish a photography room and a film development room in accordance with the radiation protection requirements stipulated by the epidemic prevention department.

⑴ Radiography room: The power of ordinary dental X-ray machines is very small, the general current is 0.5~10mA, and the focus is about 0.3mm×0.3mm~0.8mm×0.8mm. Walls are generally protected by lead sheets with a thickness of 0.5mm, and the lead equivalent is greater than 1.0mmPb. The lead sheets are buried in the walls during construction. Standard lead screens may also be used. The radiography room should be adjacent to the diagnostic and treatment room to improve work efficiency.

If a movable lead plate room is used, it only needs to accommodate one patient and an X-ray machine. The control part of the X-ray machine is placed beside the lead glass outside the lead plate room, which is more convenient to operate. If a protective wall is not installed in the photography room, a control room with protective facilities can be set up for operation.

⑵ Film processing room: Qualified clinics are equipped with digital dental X-ray machines or digital curved tomographic X-ray machines. After patients take X-rays, they are received through CCD sensors and can be displayed on the computer. Photos can be printed directly and sent to the dental treatment table through the network system for the doctor to use, without the need for a film processing room.

Clinics should generally be equipped with an automatic dental X-ray developing machine, which can be operated in a bright room. If limited by economic conditions, a small darkroom can be set up for film development. The darkroom has an area of ??4~6_ and is equipped with three pools for developing, fixing and rinsing. Due to the high indoor temperature and acidity, ventilation facilities should be installed to maintain air circulation.

There should be a bright room outside the dark room, which can prepare medicines, dry films, or sort out the X-rays that have been taken.

4. Disinfection room

⑴ Design standards for disinfection rooms: pollutants and sub-contaminants must be separated; disposable items should be initially disinfected after use and then sent to specialized departments for recycling.

⑵ Disinfection equipment for mobile phones and instruments: should include cleaning machines, maintenance oiling machines, installation sealing machines, high-temperature and high-pressure sterilizers, etc.

⑶ The environment of the disinfection room: it should be brightly lit, equipped with ventilation, dust exhaust, air sterilization and other devices. There should be a pool and sewer indoors, and the sewer should be connected to the sewage treatment station.

5 Model Room Generally, small clinics do not have a laboratory, and the repair parts can be sent to the technician processing center for production. But the model room is necessary, and the plaster model is mainly poured. The room is best located on the first floor, with an area of ??about 6~8_. A stone countertop edge with a sink should be provided. Sewers should be thick and straight, with a diameter of 150~200mm to prevent gypsum blockage. Before entering the underground drainage pipe, a gypsum settling place should be set up to settle the gypsum. Wall cabinets should be provided indoors to store plaster. Plaster model trimming machines, plaster model cutting machines, oscillators, etc. can be placed on the side table.

(2) Clinic decoration standards

The grade and style of dental clinic decoration should be determined according to the positioning of the clinic. The general requirements should highlight the professional characteristics and cultural atmosphere of the clinic, create a relaxed and comfortable treatment environment, and be conducive to the control of cross-infection in oral medical services. Among them, dental clinics with a homely and warm style that can help alleviate the fear of dental patients are becoming popular among patients abroad.

⑴The clinic should be brightly lit, and ceiling lights should be used for ceiling lighting.

⑵Good ventilation, exhaust and air disinfection facilities. It is not advisable to use a fan, and the air conditioner's filter must be easy to clean.

⑶The floor material should be smooth, wear-resistant, and non-slip. Carpets are definitely not suitable.

⑷ There should not be too many hanging objects on the wall. The paint should be made of corrosion-resistant and easy-to-clean materials. It is best to use cool colors, such as light blue or milky white, to give people a relaxing feeling.

⑸The furnishings in the clinic, including furniture, doctor’s diagnosis table, etc., should be simple and easy to clean and surface disinfect.