Current location - Plastic Surgery and Aesthetics Network - Plastic surgery and medical aesthetics - Decoration and layout skills of stomatological hospital
Decoration and layout skills of stomatological hospital
Many designers mistakenly think that the bigger and higher the hall of oral medical places, the more magnificent it will be. In fact, the oversized hall will not only increase the renovation and operation costs of investors, but also appear extremely deserted. So what kind of dental hospital decoration design is reasonable? Let's learn the decoration and layout skills of stomatological hospital!

The space of oral medical treatment should be clean, elegant and warm, and a good atmosphere should be created in the guest room to make the overall facilities of the place more perfect. The best position is reserved for the patient, and the irregular position with poor light is reserved for standby.

The waiting room and treatment room are the spaces where patients spend the longest time in outpatient service, so under the premise of limited cost, the overall design pursues simplicity and fashion, and the bright background color is coordinated with the soft lighting effect. Melodious background music creates a feeling of "home", which makes patients feel comfortable and makes people feel at home.

Decoration and layout skills of stomatological hospital

First, the external decoration design of dental clinic

1. Eye-catching clinic logo and clinic name;

2. The color of the exterior wall is consistent with the basic tone inside the clinic;

3. Oral health publicity materials can be posted on the window in the same direction as the clinic door, but they cannot be commercial, such as the manufacturer of the product and the price of the diagnosis and treatment project.

Second, the overall interior decoration layout of the dental clinic

1. The tone of the clinic should be neutral, and it is best to choose something that is easy to change.

That is, light color; 2. The clinic should be convenient for patients to enter and leave, and should take care of patients with mobility difficulties and disabled people;

3. The clinic is divided into three functional areas: reception, diagnosis and treatment, and support. Each part should be relatively independent, and patients should try not to enter the support function area;

4. It is convenient for staff to walk, and the width of the pedestrian passage in the clinic is not less than 150 cm, so as to avoid and reduce the conflict with the patient's direction;

5. The ceiling and walls are smooth and flat, and there can be no uneven decorative patterns. The coating has waterproof and mildew-proof properties;

6. Carpets can be laid in all areas except the reception room and the doctor's office;

7. Adequate lighting, use white light source, use scattered light as much as possible, and do not use chandeliers or wall lamps;

8. Have audio equipment;

9. There can be no steps inside the clinic, and there can be no threshold at the door of each room;

10. All rooms should have good sound insulation and ventilation performance. When using central air conditioning, air filtering devices and air return openings must be provided.

Outdoor air outlets shall not affect adjacent houses and units; 1 1. Doors and windows have good sealing performance. The width of the door of each room is not less than 75 cm. There can be no decorative pattern on the door panel, and no glass can be embedded.

12. All lines must be hidden lines and cannot be exposed on the ground and walls;

13. It is best to use an inductive switch for the faucet;

14. All drawer handles should be simple, smooth and easy to clean;

15. The design of the treatment room should fully consider the privacy requirements of patients.

Third, the pipeline laying requirements

1. compressed air: the inlet pressure of the equipment is 5.0-7.0 kg/cm2; ;

2. Vacuum negative pressure: the vacuum degree is not less than 85 mmHg, and the flow rate is not less than135 L/min;

3. Tap water: the pressure is 2.0 kg/cm2; ;

4. AC power supply: 220V/50Hz, with power not less than1;

5 kva. The treatment room, X-ray room and disinfection room should have independent distribution boxes to avoid mutual interference.

The piping requirements of the dental chair are as follows:

1. water supply pipe: galvanized steel pipe or plastic aluminum pipe, with a diameter of 1/2 inch, with a threaded nozzle, 50mm; from the ground;

2. Sewer pipe: galvanized steel pipe or PVC pipe, with a diameter of 1.5-2 inches, the diameter of main water pipe should be 2 inches, the nozzle is unthreaded, and the interface must be flat and smooth to prevent dirt from being stuck and blocked, which is10 mm higher than the ground;

3. Compressed air pipe: galvanized steel pipe or copper pipe, with a diameter of 1/2 inch and a threaded nozzle, 50mm; above the ground;

4. Power cord tube: galvanized steel tube with a diameter of 1/2 inches.

Or engineering plastic conduit, with a diameter of 3/8 inch, higher than the ground 10 mm, the conductor specification is 3X 1.5 mm, and the outgoing length of the conductor is100mm; 5. Negative pressure signal pipe: galvanized steel pipe with a diameter of 1/2 inch, or engineering plastic conduit with a diameter of 3/8 inch, which is 10 mm higher than the ground. The wire specification is 2X 1.0 mm, and the length of outlet pipe is 500mm.

Fourth, the waiting room decoration layout

1. The basic color of the waiting room should comply with the company's regulations;

2. The lighting in the reception room should be soft, but the lighting in the reception area should be concentrated and have sufficient intensity;

3. The height of the reception desk shall not exceed 1.2m, and the material of the desktop shall be hard, smooth, wear-resistant and easy to clean, but glass shall not be used;

4. There should be a clinic sign on the wall behind the reception desk;

5. If TV sets or other electrical appliances are placed in the waiting room, it must be ensured that there are no obvious wires and connectors within the range of personnel activities;

6. There should be a place to hang clothes for patients.

Five, treatment room decoration requirements

1. There should be no open wires indoors;

2. The use area of each treatment room shall not be less than 10 m2. The space occupied by the dental chair shall not be less than 3 meters long and 2.5 meters wide. 30 cm wide space should be reserved in front of the dental chair;

3. The light is sufficient, and a dental chair needs to be equipped with at least four 40-watt fluorescent lamps;

4. The wall is smooth and flat, but tiles are not needed;

5. The ground should be made of wear-resistant, anti-slip, corrosion-resistant and easy-to-clean materials, but not too hard;

6. Good sound insulation performance;

7. There should be side tables on both sides of the dental chair. The surface of the side table should be made of smooth, easy-to-clean and corrosion-resistant materials, and there should be no seams on the desktop;

8. There should be space for placing waste barrels on the side platform, and the waste barrels should not be exposed where patients can see them;

9. Wall cabinets can be installed on the wall, and glass doors should not be used in the wall cabinets, so that patients can't see the items in the cabinets;

10. Each treatment room should have at least one sink, and it would be more ideal if one sink could be installed in the work areas of doctors and nurses respectively. The water flow of the hand-washing pool used by nurses should be adjustable, which is convenient for nurses to mix impression materials.

2. The lighting in the reception room should be soft, but the lighting in the reception area should be concentrated and have sufficient intensity;

3. The height of the reception desk shall not exceed 1.2m, and the desktop material shall be hard, smooth, wear-resistant and easy to clean, but glass shall not be used;

4. There should be a clinic sign on the wall behind the reception desk;

5. If TV sets or other electrical appliances are placed in the waiting room, it must be ensured that there are no obvious wires and connectors within the range of personnel activities;

6. There should be a place to hang clothes for patients.

Five, treatment room decoration requirements

1. There should be no open wires indoors;

2. The use area of each treatment room shall not be less than 10 m2. The space occupied by the dental chair shall not be less than 3 meters long and 2.5 meters wide. 30 cm wide space should be reserved in front of the dental chair;

3. The light is sufficient, and a dental chair needs to be equipped with at least four 40-watt fluorescent lamps;

4. The wall is smooth and flat, but tiles are not needed;

5. The ground should be made of wear-resistant, anti-slip, corrosion-resistant and easy-to-clean materials, but not too hard;

6. Good sound insulation performance;

7. There should be side tables on both sides of the dental chair. The surface of the side table should be made of smooth, easy-to-clean and corrosion-resistant materials, and there should be no seams on the desktop;

8. There should be space for placing waste barrels on the side platform, and the waste barrels should not be exposed where patients can see them;

9. Wall cabinets can be installed on the wall, and glass doors should not be used in the wall cabinets, so that patients can't see the items in the cabinets;

10. Each treatment room should have at least one sink, and it would be more ideal if one sink could be installed in the work areas of doctors and nurses respectively. The water flow of the hand-washing pool used by nurses should be adjustable, which is convenient for nurses to mix impression materials.