Sliding door: 750~ 1500, height: 1900~2400.
Low cabinet: depth: 350~450, cabinet door width: 300 ~ 600.
TV cabinet: depth: 450-600, height: 600-700.
Single bed: width: 900, 1050,1200; Length: 1800,1860,2000,2100.
Double bed: width: 1350, 1500,1800; Length 1800,1860,2000,2100.
Round bed: diameter:1860,2125,2424 (commonly used)
Interior door: width: 800-950, hospital1200; Height:1900,2000,2100,2200,2400
Toilet kitchen door: width: 800,900; Height:1900,2000,2100
Curtain box: height:120-180; Depth: single cloth120; Double fabric 160- 180 (actual size)
Sofa: single person: length: 800-950, depth: 850-900; Cushion height: 350-420; Back height: 700-900
Double style: length:1260-1500; Depth: 800-900
Trio: Length:1750-1960; Depth: 800-900
Four-person style: length: 2320-2520; Depth 800-900
Coffee table: small, rectangular: length 600-750, width 450-600, height 380-500(380 is the best).
Medium, rectangular: length1200-1350; Width 380-500 or 600-750
Square: 750-900 in length and 430-500 in height.
Large, rectangular: length 1500- 1800, width 600-800 and height 330-420(330 is the best).
Circular: diameter 750,900, 1050,1200; Height: 330-420
Square: width 900, 1050, 1200, 1350,1500; Height 330-420
Desk: fixed: depth 450-700(600 is the best) and height 750.
Movable type: depth 650-800, height 750-780.
The lower edge of the desk is at least 580 from the ground; Length: at least 900( 1500- 1800 is the best)
Dining table: height 750-780 (general), western-style height 680-720, general square table width1200,900,750;
The width of the rectangular table is 800,900, 1050,1200; Length 1500, 1650, 1800, 2100,2400.
Round table: diameter 900, 1200, 1350, 1500, 1800.
Bookshelf: the depth is 250-400 (per grid) and the length is 600-1200; The bottom is 350-450 and the height is 800-900.
Movable cabinet: depth 450, height 1800-2000.
Wall thickness of wooden compartment: 60-100; Spacing of internal wood: length (450-600)*900.
Commonly used indoor dimensions:
1, wall size
(1) skirting board height; 80—200。
(2) Height of dado: 800-1500.
(3) Height of the hanging mirror line: 1600— 1800 (height from the center of the painting to the ground).
2. restaurants
(1) Table height: 750-790.
(2) the dining chair is high; 450—500。
(3) Diameter of round table: l500 for two persons, 800 for two persons, 900 for four persons, 5 persons 1 100, 6 persons 1 100- 1250, and 8 persons1.
(4) Square dining table size: 700×850 for two people, 0/350× 850 for four people and 2250×850 for eight people.
(5) Diameter of dining table turntable; 700—800。
(6) Table spacing: (500 seats) should be greater than 500.
(7) Main channel width: 1200— 1300.
(8) Width of internal working channel: 600-900.
(9) Lever height: 900- 1050, width 500.
(10) bar stool height; 600-750.
3. Shopping mall business hall
(1) width of single-sided double walkway: 1600.
(2) Double aisle width: 2000.
(3) Width of bilateral three-person walkway: 2300.
(4) the width of the two-way four-person walkway; 3000。
(5) Assistant counter aisle width: 800.
(6) Shop assistant merchandise counter: 600 thick and 800—l 000 high.
(7) Single backrest stand: thickness 300-500, height 1800-2300.
(8) Double-backrest vertical shelf; Thick; 600-800, height: 1800-2300
(9) Small commodity window: thickness: 500-800, height: 400- 1200.
(10) height of display platform: 400-800.
(1 1) Open rack: 400-600.
(12) radial shelf: diameter 2000.
(13) cashier: length: 1600, width: 600.
4. Hotel room
(1) Standard area: large: 25m2, medium: 16— 18m2, small: 16m2.
(2) Bed: height: 400-450mm, bed height: 850-950mm. ..
(3) bedside table: 500-700 mm high; Width: 500-800 mm.
(4) writing desk: long; 1 100— 1500mm; 450-600 mm wide and 700-750 mm high.
(5) The luggage platform is 9L0- 1070mm long, 500mm wide and 400mm high.
(6) Wardrobe: width: 800-1600-2000mm, height:1600-2000mm and depth: 500mm.
(7) Sofa: width: 600-800mm height: 350-400 mm backrest height:1000 mm.
(8) Height of clothes rack:1700—1900 mm.
5. Toilet
(1) Toilet area; 3-5 square meters.
(2) the length of the bathtub; Generally, there are three types: 1220, 1520 and 1680mm. ; Wide; 720mm, 450mm high.
(3) sit down; 750×350 mm.
(4) Flushometer: 690× 350mm.
(5) Combined washbasin: 550×4 10(mm).
(6) Shower height: 2100 mm.
(7) dressing table; Length:1350mm; ; 450 mm wide.
6. Meeting room
(1) central meeting room capacity: the length of the conference table is 600(mm).
(2) the capacity of the ring-shaped senior conference room; The length of the annular liner is 700- 1000 mm.
(3) The service channel width of the circular conference room is 600-800 mm. ..
7. Traffic space
(1) Clearance of stairwell rest platform: equal to or greater than 2100 mm.
(2) Stair runway clearance: equal to or greater than 2300mm.
(3) the room corridor is high; Equal to or greater than 2400 mm
(4) The width of the comprehensive corridor with seats on both sides is equal to or greater than 2500mm.
(5) the stair handrail is high; 850— 1 100 mm.
(6) Common dimensions of doors: width: 850-1000 mm.
(7) Common dimensions of the universe; Wide; 400-1800mm (excluding combination window)
(8) the window sill is high; 800-1200mm.
8. Table lamp
(1) Minimum height of large chandelier: 2400 mm
(2) Height of wall lamp:1500—1800 mm.
(3) The minimum diameter of the reflective lamp groove: equal to or greater than twice the diameter of the lamp tube.
(4) Height of wall bedside lamp:1200—1400 mm.
(5) Height of lighting switch:1000 mm.
9. Office furniture
(1) desk: length: 1200— 1600mm: width: 500—650mm 5h;; 700-800 mm.
(2) Office chair: high; 400-450 mm length × width: 450×450 mm.
(3) Sofa: width: 600-800 mm; Height: 350-400 mm; Back:1000 mm.
(4) coffee table; Front type: 900×400×400 (height) (mm); Central type: 900 x 900 x 400 (mm),
700×700×400 (mm); Left and right type: 600×400×400(mm).
(5) bookcase: height: 1800mm, width:1200-1500 mm; Depth: 450—500mm.
(6) Bookshelf: height: 1800mm 6 width:1000-1300mm; Depth: 350-450 mm.
★ stairs
I. stairs
1. staircase: the angle is 20. ~45。 , comfortable slope of 26. 34', that is, the length-width ratio1/2;
Second, the determination of the number of stairs
1. Public * * * staircases and corridor-style houses should generally take two staircases, except for unit-style houses;
2.2 ~ 3 floors of buildings (except hospitals, sanatoriums, nurseries and kindergartens) can meet the following requirements, and evacuation stairs can be set:
Maximum building area (m2) of each floor with fire resistance rating.
One, two, two, three 500 The sum of the number of people on the second and third floors shall not exceed 100.
Third, second and third floors 200 The sum of the number of people on the second and third floors shall not exceed 50.
There are no more than 30 people on the 4 th, 2 nd and 200 th floors.
3. For unit-type houses with nine floors and below, the construction area of each floor shall not exceed 300 m2, and the number of people shall not exceed 30, so a staircase may be provided;
4. Stairs can be provided for tower houses with a building area of not more than 500 m2 of nine floors and below.
Third, the determination of the location of the stairs
1. Stairs should be placed in obvious and easy-to-find places;
2. Stairs should not be set in the corners and edges of buildings to facilitate load transfer;
3. The stairs should have direct lighting and natural ventilation;
4. Stairwells of five-story and above buildings should have entrances and exits at the bottom; For buildings with four floors and below, the stair spacing between entrances and exits shall not exceed 15m.
Four, stair detail size
1. Step width (b) and height (h) shall meet one of the following relations:
B+h = 450mm B+2h = 600 ~ 620mm
2. The width of the stairwell should not be less than150 mm;
3. The stair section shall be at least Grade 3 and at most Grade 18; The width of the steps depends on the number of people passing by and the fire protection requirements;
(1) width of each stream = average shoulder width (550mm)+ a little lifting size (0 ~ 0~ 150mm)
(2) Fire control requires two people to go up and down each staircase at the same time, and the minimum width of the staircase is1100 ~1400 mm;
(3) The minimum width of the outdoor evacuation stair section is 800 ~ 900 mm. ..
4. Stair railings and handrails
(1) The height of the handrail surface is related to the slope of the stairs (15. ~30。 Take 900 and 30. ~45。 Take 850 and 45. ~60。 Take 800 and 60. ~75。 Take 750);
⑵ The horizontal protective railing shall not be less than1050mm; ;
(3) When the width of the stair section is greater than 1650mm (third-rate), handrails against the wall should be added; When the width of the stair section exceeds 2200mm (four people flow), an intermediate handrail should be added.
5. The clear height between the beam of the stair rest platform and the lower passage should not be less than 2000mm, and the clear height between stairs should not be less than 2200mm.
Residential nurseries, kindergartens, primary and secondary schools, shops, sanatoriums, general hospitals, bus stops, cinemas and theaters.
* * * Stairs Indoor Stairs Office Stairs Outdoor Stairs Indoor Stairs Outdoor Stairs are mainly evacuation stairs and metal ladders on the stage.
Minimum width b 250 220 260 Step slope should not be greater than 30o 280 300 280 280 Step slope should not be greater than 60o.
Maximum height h180 200150160150160.
Clear width (mm) ≥1100 ≥1000 ≥ 750 ≥ 900 ≥1400 ≥1650 ≥
The evacuation staircase in the waiting hall on the second floor leads directly to the outdoor ≥1400 ≥100 ≥11100 ≥ 600.
≥ 1400 ≥3000
The height and requirements of the railing (mm) should not be less than 900. The gap between the railing uprights should not be greater than 1 10. Handrails for children should not be higher than 600. The railings should be decorated vertically.
Clear distance ≤ 1 10 indoor railing ≥900 outdoor railing ≥1100 ≥/natural lighting and ventilation height should not be less than 900. Strong and continuous handrails shall be provided.
When other stairwells are wider than 200, measures must be taken to prevent children from climbing and sliding. In addition to setting adult handrails at a height of 0.65, children's handrails should also be set. Each stair step ≤ 18 and ≥3. The shopping mall is in five places.
When it is higher than the floor, there should be no less than two or more stairs leading to the roof. The natural lighting ward should be the main entrance staircase of the closed staircase waiting room.
For evacuation stairs, when the continuous steps are less than or equal to 18, the height will be relaxed by 10 for each additional step.