Fire hydrant is a kind of water supply equipment, which is used to put out the fire in case of fire, and is an essential element in the fire control reform of office decoration. Fire hydrants should pay attention to the following three points: First, the location has clear requirements and must be placed in public areas, such as corridors and halls, and not in independent office rooms; Second, the placement height must comply with the fire regulations, and it is not allowed to be set at will; Third, fire hydrants must be filled with water, and it is fire water supply.
Second, the fire escape in the office fire fighting
Fire escape is a very important element in the whole fire-fighting reconstruction. People can be rescued from the escape when they are in danger, so it is necessary to set fire exits in office decoration. Regarding the fire escape, the relevant departments have strict regulations: the width must be set according to the standards of fire protection design, not narrower than the minimum standards. (Evacuation walkways shall be calculated and determined according to the number of evacuees, but the minimum clear width shall not be less than1.4m.. The passage exceeding 10000 square meters shall not be less than 2.4M
Not less than 3.5 meters);
The fire exit of the office needs to be connected with the escape exit. According to the population density of different places, there are also relevant regulations on exit ports, usually no less than two. At the same time, it is forbidden to set up redundant doors and windows in the fire escape, and obstacles cannot be piled up, otherwise it will be regarded as unqualified entry.
Three, the office fire emergency lights and signs
Emergency light is a lighting tool in fire-fighting facilities, and it is the only lighting equipment after power failure in an emergency, so it is an indispensable facility in fire-fighting reconstruction in office decoration. The number and location of emergency lights should be strictly in accordance with the fire protection standards, otherwise they will not pass the fire protection acceptance. There are two main fire signs: one is evacuation sign; The second is the safety exit sign, which basically means the same thing, telling people the direction and exit when evacuating.
Fourth, the office fire spray and smoke.
Office decoration is no exception, and the decoration is equipped with spray and smoke fire protection. According to the size and scale of the office space, the fire protection design institute designs the relevant number, and the office fire protection design drawings are installed after being reviewed by the fire brigade. And every smell of smoke needs to be numbered and filed in the fire brigade. Both spray and smoke must be exposed on the ceiling, and the ceiling designed by office decoration in the later period can't be blocked.
It is forbidden for office decoration units to cap the additional partition wall to the ceiling or top, and each additional isolation room must be equipped with at least one independent smoke detector and one spray. Every 50 square meters must be equipped with at least one smoke detector and one sprinkler, and the area less than 50 square meters shall be subject to 50 square meters.
In the design of office decoration, in addition to the four points mentioned above, there are many requirements for fire fighting reconstruction, such as the provision of fire extinguishers, the posting of fire fighting publicity atlas, the notification of floor plan and so on. Office fire-fighting equipment is related to our life, and it needs to be done in strict accordance with the requirements of fire control, otherwise it will cause irreparable consequences.