Fault
Cause
Treatment method
Belt deviation
1. The belt itself is skewed
Replace some belts
2. The tail tensioning device and slide rail are deformed and derailed
Adjust and reshape
3. The frame is not straight (including the middle Frame)
Calibrate based on the center line
4. The adjusting wheel, groove, and return wheel bracket are not correct
Adjustment groove, return wheel bracket, and adjustment wheel Wheel inspection
5. The reversing drum is not straight
Adjust the level and center position of the reversing drum
6. There are debris on various drums and the glue joints are not straight.
Repair the cleaner to clean the sticky coal and re-inspect the rubber joints
7. The material is unbalanced and the coal guide chute is offset
Improve the position of the feed chute
p>8. The blanking point is incorrect
Adjust the blanking point
9. The coal retaining belt is worn on one side
Replace the coal retaining belt< /p>