Reason for failure:
1. The space for placing the prosthesis on both sides is asymmetrical, or the space for placing the prosthesis is insufficient.
2. Prosthesis is not designed according to the shape of bridge of nose.
Maintenance plan:
Take out the previously implanted prosthesis, rearrange the space for placing the prosthesis, and finally implant the prosthesis suitable for the nose shape. The reason for this situation is not the side effects of the operation, but the strength of the surgeon. Therefore, we must find a professional doctor with rich surgical experience to ensure satisfactory surgical results.
Postoperative motion of prosthesis
Reason for failure:
1. The position of prosthesis (between nasal bone and periosteum) is not suitable.
2. The prosthesis was not well fixed in the periosteum during the operation.
Maintenance plan:
Re-correct and fix the position of subperiosteal prosthesis. In the case of non-open incision, the precise technique of periosteum separation is needed, and the operation is difficult. Try to find an experienced surgeon to perform the operation.
Nose deformation caused by prosthesis
Reason for failure:
1. Excessive enlargement of the bridge of the nose with prosthesis
2. No extra rhinoplasty, only silicone rhinoplasty.
3. There is no problem with the operation, but the customer's personal skin is thin or squeezed.
Maintenance plan:
Remove the prosthesis of the nose, reshape the deformed cartilage, and use your own cartilage, dermis and other tissues to shape a natural and perfect nose.
Contraction condition
Reason for failure:
1. The part around the prosthesis hardens and contracts, resulting in skin contraction.
2. Postoperative inflammation was not treated in time.
Maintenance plan:
Reconstruction with nasal septal cartilage or donated cartilage, repair the damaged tissue of nose, restore the length and position of nasal cartilage, and finally correct the tip of nose with nasal septal cartilage or donated cartilage.
The condition of high nose bridge
Reason for failure:
Without comprehensive consideration of the whole face shape, the bridge of the nose is too high.
Maintenance plan:
Take out the prosthesis implanted before, implant the prosthesis suitable for individual face, and shape the natural nose. The bridge of the nose has a certain height, but the nostrils are wider. Only by closing the alar can we achieve better surgical results and create a natural three-dimensional beautiful nose.
The bridge of the nose is too narrow.
Reason for failure:
1. The implanted prosthesis is too narrow.
2. The skin of the nose becomes thinner, and the surgical marks are obvious.
Maintenance plan:
The ideal width of male prosthesis is 13mm and that of female prosthesis is10 mm. Nose repair removes the previously implanted prosthesis and replants a wider prosthesis suitable for the individual's face. In the case of thinning skin, surgery to increase skin thickness is needed at the same time.
The nose becomes lower.
Reason for failure:
Regardless of the weakness of nasal supporting tissue, prosthesis added during operation or other reasons, the nasal cartilage is compressed, which leads to the nose becoming lower.
Maintenance plan:
The nasal septum cartilage was used to strengthen the support of the nose, and finally other cartilage was implanted to correct the nose.