How to repair the broken integrated stove?
Give you some daily faults of the integrated stove and its maintenance methods: the display screen of the integrated stove is not bright: 1, the power cord falls off or the plug is damaged, refer to the wiring diagram, and repair or replace it after inspection and judgment. 2. If the power board or computer board is damaged, repair or replace it after inspection and judgment. The integrated stove fan does not work: 1, the power cord falls off or the plug is damaged, refer to the wiring diagram, and repair or replace it after inspection and judgment. 2. If the power board or computer board is damaged, repair or replace it after inspection and judgment. 3. If the temperature rise of the motor exceeds 125 degrees, it can return to normal after cooling, or it may be that the motor is burnt out and needs to be replaced. 4. The connecting plug of the control line has poor contact. Check the plug with reference to the circuit connection diagram to ensure good contact. 5. The capacitor is damaged and needs to be replaced. Ignition difficulty of integrated stove: 1, the ignition knob is not turned 90 degrees, the air outlet is too small, and the gas does not pass much, so it cannot burn normally. Operate the ignition knob correctly and install it in place. 2. Ignite Mars weakly, and replace the battery. 3. Whether the gas path is clear, whether the gas path between the gas main pipe and the gas branch pipe is clear, and whether the nozzle is blocked. 4. The ignition slot of the fire cover is not aligned with the ignition needle. Just rotate the aluminum cover to align it. 5. The ignition slot of the fire cover is blocked, and the plug of the ignition slot is cleaned. 6. There is more air mixed in the trachea, so the ignition time is prolonged until the air in the tube is completely exhausted. 7, ignition electrode oxidation, can be cleaned with a dry cloth. 8. The metal hose is bent or flattened. After correcting the metal hose, see if it leaks. The integrated stove often turns off automatically after ignition: 1, and there is no flame at the thermocouple (ion detection needle), which has been corrected. 2. The fire at the thermocouple is abnormal, so debug the inner ring baffle. 3. If the pulse igniter or solenoid valve is damaged, detect and replace it. The flame difference of the integrated stove is 1, and the gas path is not smooth. Whether the gas path between the gas main pipe and the gas branch pipe is smooth depends on whether the nozzle is blocked. 2. If the gas quality is poor or the bottle bottom is weak, replace the gas. 3. Burner parts are affected with damp and naturally dry after normal. 4, fire hole blockage, clean up the fire hole blockage. 5. If the fire cover and aluminum cover are not in place, put the fire cover into the locating pin. 6. The damper is not well adjusted, and the damper optimizes the flame. Abnormal fire sound of integrated stove: 1, poor gas quality or gas at the bottom of the bottle, gas should be replaced. 2, fire hole blockage, clean up the fire hole blockage. 3. If the fire cover and aluminum cover are not in place, put the fire cover into the locating pin. 4. The damper is not well adjusted, and the damper optimizes the flame. The integrated stove disinfection cabinet does not work: 1, and the power board or computer board is damaged. Repair or replace it after inspection and judgment. 2. If the cabinet door is not closed or deformed, close the cabinet door or reshape the magnetic sealing strip of the cabinet door. 3. The door control switch is damaged and replaced. The induction cooker of integrated stove is not working normally: 1. Cooking utensils do not meet the requirements directly. According to the instructions, use the cooker correctly. If the bottom of the pot is uneven, change it to a flat one. 3. The placement position deviates from the center, and the pot can be placed in the center of the ceramic plate. There is abnormal noise when the fan of integrated stove is running: the impeller is loose, not fastened and the nut is tightened. EO alarm of integrated stove: 1, power board or computer board is damaged, and it shall be repaired or replaced after inspection and judgment. 2. If the metal hose is poorly connected or cracked, please connect or replace the hose. 3. If the valve body leaks, send it to the maintenance department for repair or replace it with a new valve. 4. The kitchen smells (such as paint). Remove odor or strengthen kitchen ventilation.