(a) north-south layout, the distance between high-rise buildings and residential buildings on the north side should be less than 30 meters;
(two) the north-south layout, the distance between the high-rise building with a width of less than or equal to 40 meters and the south house should be less than 20 meters; The distance between a high-rise building with a width of more than 40 meters and the south side residence should be less than 24 meters;
(3) The building orientation is east-west, and the distance between the high-rise building and the houses on the east and west sides should be less than 24 meters;
(4) When the gable of a high-rise building is less than or equal to 15m, the distance between the gable and the house below the middle and high-rise building should be less than13m; When it is larger than 15m or when a window is opened (except for high ventilation windows), items (1), (2) and (3) of this article shall be followed; High-rise buildings are not allowed to open windows (except breathable high windows) or pick balconies. 9. Twentieth is amended as: the window spacing of non-residential high-rise buildings shall be arranged in parallel in the north-south direction, and the spacing shall not be less than 24 meters; East-west parallel arrangement, the spacing shall not be less than 20 meters. Ten, increase the "construction projects on both sides of the city's main roads, adjacent to the road side shall not have open-air balconies and solid walls." As the second paragraph of Article 31. 1 1. Item (1) of Article 50 is amended as: Public buildings, public service facilities and residences shall be implemented in accordance with the provisions of Schedule 6, Parking Indicator Table. 12. Add "The expressions below the medium and high level and below the high level in Articles 15, 16, 17 and 19 of these Provisions all contain figures." As "Guiyang city planning technology management regulations" sixtieth. Thirteen. Article 61 is amended as: Article 61 From the date of implementation of these Provisions to April 38+0, 2004, the construction projects approved by the construction detailed planning scheme shall be implemented in accordance with the approved construction detailed planning scheme, and the projects that were not approved by the construction detailed planning scheme before April 38+0, 2004 and did not apply for the Construction Project Planning Permit (Copy), as well as the newly reported construction since the date of re-promulgation of these Provisions. Article 61 is changed to article 62. 14. Delete the contents of Schedule 1 of Guiyang Urban Planning Technical Management Regulations. Schedules 2, 3, 4, 5, 6, 7 and 8 of Guiyang Urban Planning Technical Management Regulations are revised as schedules 1, 2, 3, 4, 5, 6 and 7 in turn. Fifteen, schedule seven is amended as:
Schedule 6 Index Table of Parking Spaces
order
The first kind of buildings
Indicator unit
Motorized
Vehicle indicator other vehicle indicators
1 hotel parking space/guest room 1 1.52 dining and entertainment parking space/100 m2 building area 233 office parking space/100 m2 building area 0.734 commercial parking space/100 m2 building area 0.765 stadium parking space.
Parking spaces in medical and inpatient buildings/100 m2, construction area of 0.53 10 parking spaces for independent clinics/100 m2, construction area of131parking spaces for comprehensive buildings/100 m2.
live
Villa and townhouse are divided into high-grade and low-grade.
Parking spaces/residents of first-floor residential buildings
2
/
13 commercial residential parking spaces/households 1 1.5
14 affordable residential parking space/household 0.3 15 school
Parking spaces for primary and secondary schools/100 teachers and students 0.430 16 higher education parking spaces/100 teachers and students 250 17 railway station parking spaces /3.54 18 parking spaces per thousand people on peak days of farmers' markets/100 square meters of construction area.
be filled/suffused/brimming with
(1) This table is the standard for setting parking spaces for buildings in Guiyang, and the indicators listed in the table are all buildings that should be built and can be parked.
Minimum index of parking space;
(2) Other vehicles include motorcycles, mopeds, electric bicycles and bicycle parking requirements;
(3) Outdoor ground parking spaces in residential areas should generally not exceed10% of the total parking spaces;
(4) The parking spaces in this table are based on cars;
(5) Other vehicle indicators can be converted into indicators by vehicle110.
Remarks (1) This table is the setting standard of building parking spaces in Guiyang, and the configuration indicators listed in the table are the minimum indicators of building parking spaces;
(2) Other vehicles include motorcycles, mopeds, electric bicycles and bicycle parking requirements;
(3) Outdoor ground parking spaces in residential areas should generally not exceed10% of the total parking spaces;
(4) The parking spaces in this table are based on cars;
(5) Other vehicle indicators can be converted into indicators by vehicle110.