Current location - Plastic Surgery and Aesthetics Network - Jewelry brand - Calibration method of Hengxin electronic platform scale
Calibration method of Hengxin electronic platform scale
They are all new.

Calibration description of Hengxin electronic pricing scale

Calibration instructions for electronic pricing scales

1。 Please turn off the machine first, and then press and hold the "Pricing Unit Key" before turning on the machine. Press the "unit valuation key" again,

2. Enter the key "1, 9, 5, 6", and then enter the numeric key "1".

3. The visual total price window displays the weight value to be loaded, load the corresponding weight on the scale, and then press the "."(decimal point) key to confirm.

4. The total price window displays the weight value of the second point to be reloaded, load the corresponding weight on the scale, and then press the "."(decimal point) key to confirm.

5. The total price window displays the weight value of the third point to be reloaded, load the corresponding weight on the scale, and then press the "."(decimal point) key to confirm.

6. The visual total price window displays "10000", and then press "Pricing Unit" to exit. The calibration is over.

Weight value of range load

Number one, number two and number three.

3 kg 1 kg 2 kg 3 kg

6 kg, 2 kg, 4 kg, 6 kg

15kg 5kg 10kg 15kg

30 kg 10 kg 20 kg 30 kg

60 kg, 20 kg, 40 kg, 60 kg

150kg100kg150kg

300kg 100Kg 200Kg 300Kg

600 kg, 200 kg, 400 kg, 600 kg

Calibration description of Hengxin electronic weighing instrument

Calibration instructions for electronic scales

1. Press [Open/Peel] and release immediately.

2. Before the machine returns to zero, press [[MODE]] (function key) three times to enter the machine calibration state.

Step 3 wait for about three seconds

4. If the display does not show zero, please press [on/tare] once to zero. Then the display alternately displays: "25.00" and "—"(Take 150 kg as an example, the displayed figures are different for different scales) "25.00": the weight value to be loaded when debugging the scale, with the unit of "kg"; "-"is the prompt to load the weight.

5. Load the weight value according to the displayed prompt number, and then press the [[MODE]] key.

6. The monitor alternately displays "25.00" and "oooo". "oooo": means to wait for the scale to stabilize and record the weight value.

7. Then the monitor alternately displays "100.00" and "-". (Take 150kg as an example, different scales display different numbers) "100.00": it is the weight value to be loaded when the scale is debugged, and the unit is "kg"; "-"is the prompt to load the weight.

8. Load the weight value according to the displayed prompt number, and then press the [[MODE]] key.

9. The monitor alternately displays "100.00" and "oooo". "oooo": means to wait for the scale to stabilize and record the weight value.

10. Then the monitor alternately displays "150.00" and "-". (Take 150 kg as an example, different scales display different numbers) "150.00": it is the weight value to be loaded when the scale is debugged, and the unit is "kg"; "-"is the prompt to load the weight.

1 1. Load the weight value according to the displayed prompt number, and then press the [[MODE]] key.

12. The monitor alternately displays "150.00" and "oooo". "oooo": means to wait for the scale to stabilize and record the weight value.

13. After recording, the machine displays "End" and the calibration is completed.

14. press the "OFF" key to turn off the machine, and then press [ON/TARE] (power on key) to enter the normal weighing state.

Weight value of range load

Number one, number two and number three.

150g 25g100g150g

300 grams 50 grams 200 grams 300 grams

600g100g 400g 600g

1500g 250g1000g1500g

3 kg 500 g 2 kg 3 kg

6kg 1Kg 4Kg 6Kg

15kg 2.5kg 10kg 15kg

30 kg, 5 kg, 20 kg, 30 kg

60kg 10Kg 40Kg 60Kg

150kg 25kg 100kg 150kg

300 kg, 50 kg, 200 kg, 300 kg

600kg 100Kg 400Kg 600Kg

1500kg 250kg 1000kg 1500kg

Description of calibration of Hengxin electronic counting scale

Calibration instructions for electronic counting scales

1. First turn off the machine, and press and hold the single setting key before turning on the machine.

2. Enter the key "1, 9, 5, 6", and then enter the numeric key "1".

3. The visible total window displays the weight value to be loaded, load the corresponding weight on the scale, and then press the "."(decimal point) key to confirm.

4. The total window displays the weight value of the second point to be reloaded, load the corresponding weight on the scale, and then press the "."(decimal point) key to confirm.

5. The total window displays the weight value of the third point to be reloaded, load the corresponding weight on the scale, and then press the "."(decimal point) key to confirm.

6. The main visual window displays "10000", and then press the "Single Set" key to exit. The calibration is over.

Weight value of range load

Number one, number two and number three.

1.5 kg 500g1000g1500g

3 kg 1 kg 2 kg 3 kg

6 kg, 2 kg, 4 kg, 6 kg

15kg 5kg 10kg 15kg

30 kg 10 kg 20 kg 30 kg

60 kg, 20 kg, 40 kg, 60 kg

150kg100kg150kg

Heng Xin electronic kitchen scale description

Calibration instructions for electronic kitchen scales

1. Start the machine first. After the machine returns to zero, press the ON/OFF key four times to display a set of data directly.

2. Press the power-on key again to visually display the weight value to be loaded (that is, the maximum range value of the machine);

3. Load the corresponding weights, and press on/off key for confirmation;

4. After calibration, the machine will display the maximum range value.

Hengxin jewelry scale calibration instructions

Calibration instructions for jewelry scales

1. Start the machine first. After the machine returns to zero, press the ON/OFF key four times to display a set of data directly.

2. Press the power-on key again to visually display the weight value to be loaded (that is, the maximum range value of the machine);

3. Load the corresponding weights, and press on/off key for confirmation;

4. After calibration, the machine will display the maximum range value.

Setting up the method of hanging weight calibration (Wan Tai).

13686292690

Setting up the method of hanging weight calibration (Wan Tai).

Correction:

Before calibration, the corrector △ should be set correctly. The corrector is used to hold the input number up and shift it once before pressing it. * Select, △= 1.3 pin short circuit *= 1.2 pin short circuit.

1. Press △ to display CAL 5B.

2. Press * to display calibration 00.

3. Press * to display all weighing.

4. Press △ display 000.000, input the weight value to be corrected, and release the weight.

5. Press * to display the weight value.

6. Take off the weights and braces, OK.

Settings: press △ to display CAL.5B, △ * to display D0, input sensing quantity (use △), * to display the last preset precision value, △ to display 000.000 input precision, and * is zero.

Shanghai Yin Zhong

1, short circuit (closed state)

2. Turn on the machine and display zero (press "zero").

3. Put the weight (at least 1/3Max) and enter the weight value (15kg means 15000).

4. Press "Clear"

Step 5 turn it off

6, short circuit reset

Calibration method of top ES-6KCH electronic scale

13686292690

Calibration method of top ES-6KCH electronic scale

1.

Press the button to turn on the machine.

2.

Enter the password 888888(6 octets)

3.

Press the button several times until CAL appears.

4.

Press the button again and 0.0000 (flashing) will appear.

5. Press the button again, and 3.0000 will appear. Add more.

6. Press the button again, and 6.0000 will appear, plus the code.

7. Press the button again, and then press the setting to clear, OK.