X Kaifeng ACS-H 1 platform scale calibration method
Calibration method of Kaifeng ACS-H 1 platform scale. When the weighing scale is turned on manually, enter "zero, peel, zero" and let go. If 06-03 is displayed, press Peeling, load the weight to be corrected (/1/2 weighing), and press "zero" to correct.
Calibration method of Haiyida waterproof scale
Press 78 19- release weight-input code value-accumulation when starting the machine.
Xinniaoxin tablets
Calibration password; 989.68
Adjust the settings; 989.78 【 Round off. Gold]
Tri-peak 4V calibration
208 green shell; 228 peeling -228
2 18 white shell; 202 18- peeling -202 18
Red dragon,
592.56- Peeling-1- Peeling
Press 1 to change the range.
Press 2 to change the scale.
Press 3- to put the weight
Input Code Value-Zero-Stripping
Crash after entering the wrong password; Short circuit boot-mode-enter 592.56 or 59256- peel-click the decimal point as 100KG to display [10-]. 02] Press Accumulate-Press 0- Strip.
the golden phoenix
Password 97.36- Peeling-Accumulating-Loading-Accumulating
Type 9 18; Password 97.36- Peel-After displaying CAL-Store-Display DC[ Indicator Value]-Display POE3[ Bit Display]-Display 30000[ Maximum Weight]-Display F5- Store-Display the added weight value prompted-
Attention; Because of the memory function of 24C02, when adjusting the market weight, enter 97.36- Peeling-Storage-Storage-Display the prompt weight value, and enter 20000- set to zero.
Bit means POE3 cannot be changed, and it will be changed to G or without decimal point.
All fonts are displayed in dark colors;
The 7 153 tertiary tube on the motherboard is broken, and the 4530 is broken; It does not display when it is turned on.
Decimal shift of unit price window; Press and hold for 0.3 seconds after turning on the machine.
Bench scale calibration; Boot-9736-Peel- Play the prompt weight value -Peel- Display the weight and turn it off.
New parameter settings:
Boots -597.38- Peeling
Press 2- to rotate the city.
Press four rounds.
Press 7 to modify the division value.
Press store memory-press zero to confirm and return to weighing state.
Fenghua LCD calibration 20 1 1-5-22
At the same time, which 9 1.37- weighting-input code value-accumulation?
Fenghua dry battery calibration
Boot-storage -42. 15- storage -30000- storage -5- storage-release 15KG weight-storage-input weight value-
Fenghua Zhenghengtai Scale Calibration 20 1 1-5-22
Boot -8026- Store-Change-Repeat-Clear-Input Code Value-Strip.
Calibration description of Hengxin electronic pricing scale
Calibration instructions for electronic pricing scales
1。 Please turn off the machine first, and then press and hold the "Pricing Unit Key" before turning on the machine. Press the "unit valuation key" again,
2. Enter the key "1, 9, 5, 6", and then enter the numeric key "1".
3. The visual total price window displays the weight value to be loaded, load the corresponding weight on the scale, and then press the "."(decimal point) key to confirm.
4. The total price window displays the weight value of the second point to be reloaded, load the corresponding weight on the scale, and then press the "."(decimal point) key to confirm.
5. The total price window displays the weight value of the third point to be reloaded, load the corresponding weight on the scale, and then press the "."(decimal point) key to confirm.
6. The visual total price window displays "10000", and then press "Pricing Unit" to exit. The calibration is over.
Weight value of range load
Number one, number two and number three.
3 kg 1 kg 2 kg 3 kg
6 kg, 2 kg, 4 kg, 6 kg
15kg 5kg 10kg 15kg
30 kg 10 kg 20 kg 30 kg
60 kg, 20 kg, 40 kg, 60 kg
150kg100kg150kg
300kg 100Kg 200Kg 300Kg
600 kg, 200 kg, 400 kg, 600 kg
Calibration description of Hengxin electronic weighing instrument
Calibration instructions for electronic scales
1. Press [Open/Peel] and release immediately.
2. Before the machine returns to zero, press [[MODE]] (function key) three times to enter the machine calibration state.
Step 3 wait for about three seconds
4. If the display does not show zero, please press [on/tare] once to zero. Then the display alternately displays: "25.00" and "—"(Take 150 kg as an example, the displayed figures are different for different scales) "25.00": the weight value to be loaded when debugging the scale, with the unit of "kg"; "-"is the prompt to load the weight.
5. Load the weight value according to the displayed prompt number, and then press the [[MODE]] key.
6. The monitor alternately displays "25.00" and "oooo". "oooo": means to wait for the scale to stabilize and record the weight value.
7. Then the monitor alternately displays "100.00" and "-". (Take 150kg as an example, different scales display different numbers) "100.00": it is the weight value to be loaded when the scale is debugged, and the unit is "kg"; "-"is the prompt to load the weight.
8. Load the weight value according to the displayed prompt number, and then press the [[MODE]] key.
9. The monitor alternately displays "100.00" and "oooo". "oooo": means to wait for the scale to stabilize and record the weight value.
10. Then the monitor alternately displays "150.00" and "-". (Take 150 kg as an example, different scales display different numbers) "150.00": it is the weight value to be loaded when the scale is debugged, and the unit is "kg"; "-"is the prompt to load the weight.
1 1. Load the weight value according to the displayed prompt number, and then press the [[MODE]] key.
12. The monitor alternately displays "150.00" and "oooo". "oooo": means to wait for the scale to stabilize and record the weight value.
13. After recording, the machine displays "End" and the calibration is completed.
14. press the "OFF" key to turn off the machine, and then press [ON/TARE] (power on key) to enter the normal weighing state.
Weight value of range load
Number one, number two and number three.
150g 25g100g150g
300 grams 50 grams 200 grams 300 grams
600g100g 400g 600g
1500g 250g1000g1500g
3 kg 500 g 2 kg 3 kg
6kg 1Kg 4Kg 6Kg
15kg 2.5kg 10kg 15kg
30 kg, 5 kg, 20 kg, 30 kg
60kg 10Kg 40Kg 60Kg
150kg 25kg 100kg 150kg
300 kg, 50 kg, 200 kg, 300 kg
600kg 100Kg 400Kg 600Kg
1500kg 250kg 1000kg 1500kg
Description of calibration of Hengxin electronic counting scale
Calibration instructions for electronic counting scales
1. First turn off the machine, and press and hold the single setting key before turning on the machine.
2. Enter the key "1, 9, 5, 6", and then enter the numeric key "1".
3. The visible total window displays the weight value to be loaded, load the corresponding weight on the scale, and then press the "."(decimal point) key to confirm.
4. The total window displays the weight value of the second point to be reloaded, load the corresponding weight on the scale, and then press the "."(decimal point) key to confirm.
5. The total window displays the weight value of the third point to be reloaded, load the corresponding weight on the scale, and then press the "."(decimal point) key to confirm.
6. The main visual window displays "10000", and then press the "Single Set" key to exit. The calibration is over.
Weight value of range load
Number one, number two and number three.
1.5 kg 500g1000g1500g
3 kg 1 kg 2 kg 3 kg
6 kg, 2 kg, 4 kg, 6 kg
15kg 5kg 10kg 15kg
30 kg 10 kg 20 kg 30 kg
60 kg, 20 kg, 40 kg, 60 kg
150kg100kg150kg
Heng Xin electronic kitchen scale description
Calibration instructions for electronic kitchen scales
1. Start the machine first. After the machine returns to zero, press the ON/OFF key four times to display a set of data directly.
2. Press the power-on key again to visually display the weight value to be loaded (that is, the maximum range value of the machine);
3. Load the corresponding weights, and press on/off key for confirmation;
4. After calibration, the machine will display the maximum range value.
Hengxin jewelry scale calibration instructions
Calibration instructions for jewelry scales
1. Start the machine first. After the machine returns to zero, press the ON/OFF key four times to display a set of data directly.
2. Press the power-on key again to visually display the weight value to be loaded (that is, the maximum range value of the machine);
3. Load the corresponding weights, and press on/off key for confirmation;
4. After calibration, the machine will display the maximum range value.
Setting up the method of hanging weight calibration (Wan Tai).
13686292690
Setting up the method of hanging weight calibration (Wan Tai).
Correction:
Before calibration, the corrector △ should be set correctly. The corrector is used to hold the input number up and shift it once before pressing it. * Select, △= 1.3 pin short circuit *= 1.2 pin short circuit.
1. Press △ to display CAL 5B.
2. Press * to display calibration 00.
3. Press * to display all weighing.
4. Press △ display 000.000, input the weight value to be corrected, and release the weight.
5. Press * to display the weight value.
6. Take off the weights and braces, OK.
Settings: press △ to display CAL.5B, △ * to display D0, input sensing quantity (use △), * to display the last preset precision value, △ to display 000.000 input precision, and * is zero.
Shanghai Yin Zhong
1, short circuit (closed state)
2. Turn on the machine and display zero (press "zero").
3. Put the weight (at least 1/3Max) and enter the weight value (15kg means 15000).
4. Press "Clear"
Step 5 turn it off
6, short circuit reset
Calibration method of top ES-6KCH electronic scale
13686292690
Calibration method of top ES-6KCH electronic scale
1.
Press the button to turn on the machine.
2.
Enter the password 888888(6 octets)
3.
Press the button several times until CAL appears.
4.
Press the button again and 0.0000 (flashing) will appear.
5. Press the button again, and 3.0000 will appear. Add more.
6. Press the button again, and 6.0000 will appear, plus the code.
7. Press the button again, and then press the setting to clear, OK.
Penguin weighing machine
4V password
Storage -9845- Storage
Measuring stability performance; Storage-123- storage (the code in the motherboard is 3 times)
magpie
Password 6 199- Skinning-1- Press 3 after 5 steps of skinning.
Measuring stability performance
73358- Skinning-128- Skinning (overall code is between+and 2)
Gold;
73358- Peeling -79- Peeling
Rounding;
158- peeling-13- peeling
158- peeling -3- peeling
Yongkang Yu Hao electronic scales
Password 6895
Calibration; Boot-Save -6895- Save-Everything else is as usual.
Calibration method of winning platform scale 20 1 1-5-22
Short-circuit boot-after the internal code appears-press the change -7- display-put the weight back-enter the weight value-clear the change -9.
Fenghua Jinyi 20 1 1-5-22
Store -5976- Store-Place Weight-Store-Enter Code Value-Store-Enter Maximum Weight-Store-Index Value-Store.
The backlight is constant.
Fenghua weighbridge 2011-5-221368 6292690
Power on-press the calibration key-blink 1{ division value}-press the arrow keys to select-confirm the key to confirm-display the weight to be put-press the arrow keys to select-such as 60.00- press confirm-
Zero adjustment (resolution)
After startup-press Calibration+Counting+Peeling at the same time-display ADD 1 00-press the arrow keys to display Add10/-press OK- display ADD2 00-press the arrow keys to display add 20 1- press OK-
Xiangshan je-212011-5-221368 6292690
Press Enter to start the machine-after Xiangshan CAL unit price-press 357- put 20KG weight-press Enter-Xiangshan weight is 20.000.